This article will show how to find the entrapment board, bypass it and test if its causing any issues.
- To check if the entrapment board is faulty you need to open up the gate to find the
entrapment board.
- The entrapment board looks like this:
- To bypass the entrapment board, disconnect the cable coming from the entrapment board
going to the gate PCB (connection 1) and the cable coming from the motor (connection 2).
- Now put the cable coming from the motor where the cable from the entrapment board to the
gate PCB was connected before. - Try the function after and see if the issue remains. If the issue gets resolved, please reach out
to the customer to arrange replacement.
NOTE: Please remember to put the cables as they were before after testing if entrapment board was not faulty.
Additional video - How to change
Recommended spare part
- If the Entrapment Board is faulty, below spare part needs to be ordered.